Device integrations
PV inverters
The PV inverters and data loggers the Voltmasters EMS reads and curtails: directly or through a data logger, and the connection per brand.
The EMS monitors the PV production and curtails the active power when the site asks for it: at negative prices, under an export limit or for zero export. Where the inverter offers it, it also controls the reactive power.
Directly or through a data logger
flowchart LR
C["Voltmasters Controller"] -->|"directly"| O1["Inverter"]
C -->|"through a data logger"| D["Data logger"]
D --> O2["Inverter"]
D --> O3["Inverter"]
- Directly: the EMS reads and curtails each inverter separately.
- Through a data logger: the EMS sees the aggregated production of the installation and, where the data logger supports it, curtails the installation as a whole.
If an inverter only speaks RS485, make it reachable over the network with an RS485 to Modbus TCP converter, such as the EP E300.
Brands
| Brand | Connection |
|---|---|
| ABB | Modbus TCP (SunSpec) |
| Fronius | Modbus TCP (SunSpec) |
| GoodWe | Modbus TCP through an RS485 converter, or RTU over TCP |
| Growatt | Modbus TCP through the ShineMaster, or RS485 through a converter |
| Huawei | Modbus TCP or RS485, directly or through the SmartLogger 3000 |
| SMA | Modbus TCP, directly or through the Data Manager |
| Solar-Log | Through the Solar-Log data logger |
| SolarEdge | Modbus TCP on port 1502, SolarEdge’s own protocol |
| SolaX | Modbus TCP, or RS485 through a converter |
| Solis | Through the Solis data logger over Modbus TCP |
| Sungrow | Modbus TCP |
| SunSpec (generic) | Modbus TCP, for any SunSpec-compliant inverter |
All models per brand are in the overview list.