Energy meters integration
The SMA Data Manager as grid meter
When the energy meter at the grid connection point, for example an SMA Energy Meter, sends its values to the SMA Data Manager, Voltmasters EMS reads that measurement through the Data Manager over Modbus TCP.
Supported devices
- Data Manager (grid connection point)
The Data Manager M (EDMM-10), M Lite (EDMM-10.A) and L (EDML-10), as model Data Manager (grid connection point) with slave id 2 prefilled. Read only. Available from controller version 0.0.341.
What the EMS gets out of your SMA Data Manager installation
- Real-time measurement on the grid connection as the basis for every control action
- Submetering per installation section or consumer
- Accurate data for peak shaving and injection limiting
- Reporting and cost analysis in the platform
- Mix all brands in a single metering setup
Why the Data Manager as energy meter
An SMA Energy Meter only sends its measurements to the Data Manager. The EMS reads them there, so the grid measurement is available for peak shaving and the limits of the connection without an extra meter. When the value of a phase is missing, the EMS keeps no partial total.
The technical bit, in short
- Connection over Modbus TCP; slave id 2 (the system unit) is prefilled
- Active and reactive power, voltage, current and power factor per phase; no grid frequency
- Incidents for a system fault or a warning of the Data Manager
How it works
How your SMA Data Manager connects to the EMS
Voltmaster Controller in the cabinet
The industrial DIN-rail controller sits next to the installation and runs the optimisation locally, even without internet.
Connect over the local network
You connect the device following the step-by-step guide in our documentation. We assist with commissioning on your first project.
Configure and go live
The installation appears in the platform: dashboards, control and monitoring are active right away.
Other energy meters we control
All integrations →FAQ
Questions about the SMA Data Manager integration
Can the same Data Manager also steer my PV?
Yes. Add the Data Manager twice: as PV inverter to limit the production, and as energy meter to read the measurement at the grid connection point.
Does the system keep working when the internet drops?
Yes. The Voltmaster Controller runs the optimisation locally in the cabinet. If the connection drops, control, peak shaving and the safety limits simply stay active.
How do I connect a SMA Data Manager as energy meter to the EMS?
The Voltmaster Controller connects to the device over the local network. The step-by-step instructions are in our documentation, and as a certified partner we guide your first commissioning from start to finish.
Ready to make your first project pay off?
Tell us about your next installation. We will show you the platform, help you build the business case and guide you from first quote to certification.
Want to run the numbers first? Try the PV & battery simulator ↗