Energy meters integration
The meter behind the Huawei SmartLogger as a measuring point
A Huawei SmartLogger passes on the measurements of the power meter behind it. Voltmasters EMS reads that meter through the SmartLogger, also when the PV and the batteries are not added to the platform through the SmartLogger.
Supported devices
- SmartLogger
The model SmartLogger under energy meters, with slave id 11 prefilled: Huawei's default address for the power meter behind a SmartLogger. Available from controller version 0.0.341. The same SmartLogger can also be added as PV (SmartLogger 3000) or as battery PCS (SmartLogger Hybrid).
What the EMS gets out of your Huawei SmartLogger installation
- Real-time measurement on the grid connection as the basis for every control action
- Submetering per installation section or consumer
- Accurate data for peak shaving and injection limiting
- Reporting and cost analysis in the platform
- Mix all brands in a single metering setup
Why the SmartLogger as energy meter
On many Huawei installations the grid meter is already connected to the SmartLogger. The EMS reads that meter through the same gateway, on the meter's own address, so no extra meter has to be installed. When the gateway reports the meter as disconnected, the EMS raises an incident.
The technical bit, in short
- Connection over Modbus TCP to the SmartLogger; slave id 11 is prefilled
- The SmartLogger passes on the readings with a delay of a few seconds
- Incident when the gateway reports the meter as disconnected
How it works
How your Huawei SmartLogger connects to the EMS
Voltmaster Controller in the cabinet
The industrial DIN-rail controller sits next to the installation and runs the optimisation locally, even without internet.
Connect over the local network
You connect the device following the step-by-step guide in our documentation. We assist with commissioning on your first project.
Configure and go live
The installation appears in the platform: dashboards, control and monitoring are active right away.
Other energy meters we control
All integrations →FAQ
Questions about the Huawei SmartLogger integration
When do I add the SmartLogger as energy meter?
When the SmartLogger only has to pass on the measurements of its power meter, for example the grid meter. When you also steer the PV or the batteries through the SmartLogger, choose the PV or battery PCS role: those take the meters behind it along.
Does the system keep working when the internet drops?
Yes. The Voltmaster Controller runs the optimisation locally in the cabinet. If the connection drops, control, peak shaving and the safety limits simply stay active.
How do I connect a Huawei SmartLogger as energy meter to the EMS?
The Voltmaster Controller connects to the device over the local network. The step-by-step instructions are in our documentation, and as a certified partner we guide your first commissioning from start to finish.
Ready to make your first project pay off?