Skip to content

SunSpec energy meters as a measuring point

SunSpec is an open standard for the Modbus registers of inverters and meters. Voltmasters EMS reads every energy meter that offers a SunSpec meter model, with the Fronius Smart Meter IP as the first device, and uses that measurement on the grid connection or as a submeter.

SunSpec logo

Supported devices

  • Fronius Smart Meter IP
  • Generieke SunSpec-meter

The Fronius Smart Meter IP, with slave id 1 prefilled, and as a generic model every energy meter with SunSpec meter model 201 to 204 or 211 to 214. Available from controller version 0.0.341.

What the EMS gets out of your SunSpec installation

  • Real-time measurement on the grid connection as the basis for every control action
  • Submetering per installation section or consumer
  • Accurate data for peak shaving and injection limiting
  • Reporting and cost analysis in the platform
  • Mix all brands in a single metering setup

Why one SunSpec integration is enough

The EMS finds out which SunSpec meter model the meter offers by itself: single phase, split phase, wye or delta, in integer or floating point values (models 201 to 204 and 211 to 214). It reads the power, the values per phase, the frequency and the import and export counters. A value the meter does not offer is shown as not measured instead of zero. The event flags of the meter become incidents in the platform.

The technical bit, in short

  • Connection over Modbus TCP; the Fronius Smart Meter IP has slave id 1 prefilled
  • The SunSpec meter model is found automatically
  • Positive power is import from the grid
  • Incidents for a meter power failure, under- and overvoltage, a low power factor, a missing sensor and overcurrent
Full instructions in the documentation

How your SunSpec connects to the EMS

Voltmaster Controller in the cabinet

The industrial DIN-rail controller sits next to the installation and runs the optimisation locally, even without internet.

Connect over the local network

You connect the device following the step-by-step guide in our documentation. We assist with commissioning on your first project.

Configure and go live

The installation appears in the platform: dashboards, control and monitoring are active right away.

Questions about the SunSpec integration

Which energy meters does the SunSpec integration support?

Every energy meter that offers SunSpec meter model 201 to 204 or 211 to 214, over Modbus TCP. The Fronius Smart Meter IP is listed as its own model, with slave id 1 prefilled.

Which values does the EMS read?

The power, the voltage, current and power per phase, the frequency and the import and export counters. Positive power is import from the grid.

Does the system keep working when the internet drops?

Yes. The Voltmaster Controller runs the optimisation locally in the cabinet. If the connection drops, control, peak shaving and the safety limits simply stay active.

How do I connect a SunSpec energy meter to the EMS?

The Voltmaster Controller connects to the device over the local network. The step-by-step instructions are in our documentation, and as a certified partner we guide your first commissioning from start to finish.

Ready to make your first project pay off?

Tell us about your next installation. We will show you the platform, help you build the business case and guide you from first quote to certification.

Want to run the numbers first? Try the PV & battery simulator ↗