Blitz Power Station, smartly controlled

The Blitz Power Station (BPS) runs on a Phoenix Contact CHARX charge controller. Voltmasters EMS connects to the whole station over Modbus TCP, steers the charging current per charging point and spreads the charging within the grid connection, together with the battery, the PV and the consumption of the site.

Blitz

Supported devices

  • Power Station (BPS)

The Power Station (BPS), AC, with every charging point of the station in one device. Available from controller version 0.0.341.

What the EMS gets out of your Blitz installation

  • Load balancing within the limit of the grid connection
  • Charge at the cheapest moments, including negative prices
  • Priorities per charge point, the fleet comes first
  • Interplay with battery and PV for extra charging power
  • Monitoring of every charging session

Why installers combine Blitz and Voltmasters

One device in the platform covers the whole station: the station reports how many charging points it has and every charging point becomes a connector. The EMS writes a maximum charging current per charging point, so charging moves along with the rest of the site. A pause sets the current to 0 A and withdraws the charging release. If the EMS drops out, every charging point falls back to 6 A after 60 seconds.

The technical bit, in short

  • Connection over Modbus TCP, slave id 1
  • The station reports its number of charging points; every charging point becomes a connector
  • Set the load management in the Blitz web interface to External EMS with Other EMS, otherwise the station overwrites the charging current
  • This also switches off the station's own protection of the load circuit: cover it on site
  • Charging current per charging point from 6 A, pause with 0 A
Full instructions in the documentation

How your Blitz connects to the EMS

Voltmaster Controller in the cabinet

The industrial DIN-rail controller sits next to the installation and runs the optimisation locally, even without internet.

Connect over the local network

You connect the device following the step-by-step guide in our documentation. We assist with commissioning on your first project.

Configure and go live

The installation appears in the platform: dashboards, control and monitoring are active right away.

Questions about the Blitz integration

Which Blitz charger does Voltmasters support?

The Blitz Power Station (BPS), with a Phoenix Contact CHARX charge controller, over Modbus TCP. One device covers every charging point of the station.

What happens when the connection with the EMS drops?

While the EMS steers, it keeps a watchdog alive on every charging point. If the EMS stays away for 60 seconds, the charging point falls back to 6 A and the car keeps charging at that current.

Does the system keep working when the internet drops?

Yes. The Voltmaster Controller runs the optimisation locally in the cabinet. If the connection drops, control, peak shaving and the safety limits simply stay active.

How do I connect a Blitz Power Station to the EMS?

The Voltmaster Controller connects to the device over the local network. The step-by-step instructions are in our documentation, and as a certified partner we guide your first commissioning from start to finish.