SMA Sunny Tripower under control, from 3 to 110 kW

SMA inverters hang on rooftops all over Flanders. Voltmasters EMS connects to them directly over Modbus TCP and manages injection automatically: curtailing during negative prices, zero injection where the grid operator requires it and real-time monitoring of production.

SMA logo

Supported devices

  • STP3
  • STP4
  • STP5
  • STP6
  • STP8
  • STP10
  • STP50
  • STP110

The full Sunny Tripower series, from 3 to 110 kW. A different SMA device with Modbus TCP? Just ask us.

What the EMS gets out of your SMA installation

  • Automatic curtailment during negative prices
  • Injection limiting, up to zero injection on the grid connection
  • Align production with battery, EV chargers and site consumption
  • Yield monitoring with alerts on deviations
  • Ready for the connection requirements of the grid operator

Why installers combine SMA and Voltmasters

A PV installation without control also injects when electricity earns nothing or the grid connection gets overloaded. The EMS automatically limits the Sunny Tripower and aligns production with batteries, EV chargers and the site's consumption. The inverter becomes an active part of the energy strategy instead of a blind producer.

The technical bit, in short

  • Connection over Modbus TCP, port 502
  • Controller and inverter on the same local network
  • Enable Modbus in the inverter's web interface with an installer login
Full instructions in the documentation 

How your SMA connects to the EMS

Voltmaster Controller in the cabinet

The industrial DIN-rail controller sits next to the installation and runs the optimisation locally, even without internet.

Connect over the local network

You connect the device following the step-by-step guide in our documentation. We assist with commissioning on your first project.

Configure and go live

The installation appears in the platform: dashboards, control and monitoring are active right away.

Questions about the SMA integration

Which SMA inverters does Voltmasters support?

The Sunny Tripower series: STP3, STP4, STP5, STP6, STP8, STP10, STP50 and STP110. Do you have another SMA device with Modbus TCP? Get in touch and we will look into it together.

How does the EMS connect to the SMA inverter?

Over Modbus TCP on port 502. You enable Modbus once in the inverter's web interface (Device Parameters, External Communication) with an installer login. The Voltmaster Controller and the inverter must be on the same local network.

Can the EMS curtail production during negative prices?

Yes. The EMS automatically reads the day-ahead prices and limits the inverter when injecting costs money. A fixed injection limit or full zero injection is also possible.

Does this work together with hardware from another brand?

Yes, the EMS is brand-independent. A battery, PV inverter, EV chargers and meters from different manufacturers are controlled together as one optimised system.

Ready to make your first project pay off?

Tell us about your next installation. We will show you the platform, help you build the business case and guide you from first quote to certification.