# Alpitronic HYC DC charger

> Supported devices: HYC50, HYC150, HYC200, HYC300, HYC400 and HYC1000

Source: https://voltmasters.io/en/docs/device-integrations/ev-chargers/alpitronic-hyc-dc-charger/

> **Note**
>
> This manual assumes the charger has already been physically installed and commissioned. After these steps, the charger is ready for connection to our EMS.

1. **Log in**
   
   -   Navigate to the charger’s IP address in your web browser.
       
   -   Log in using the default credentials or the previously configured password.
       
       (default user = admin, default password = admin123).
       
   -   Once logged in, the main dashboard appears.
2. ![A browser login prompt for the charger web interface at its IP address, with the user name admin filled in.](https://voltmasters.io/assets/docs/unknown.webp)
3. ![The Alpitronic HyperCharger configuration home with the Network, Status, OCPP, General, Password and Reset sections, and the CCS connector status alongside.](https://voltmasters.io/assets/docs/unknown-2.webp)
4. **Check network settings**
   
   -   Navigate to the **Network** menu.
   -   Verify the network details and modify the local IP address if required for the location.
   -   Once the details are correct, click **Save Configuration** and confirm your changes.
5. ![The IP configuration page of the charger with manual mode selected, and the static address, subnet mask, gateway and DNS servers filled in.](https://voltmasters.io/assets/docs/unknown-3.webp)
6. **Activate Modbus**
   
   -   Go to the **General** menu and select the **Power** tab.
   -   Locate **Modbus Enabled** and set it to **True**.
   -   Click **Save Configuration** to store this setting.
7. ![The Alpitronic HyperCharger configuration home with the Network, Status, OCPP, General, Password and Reset sections, and the CCS connector status alongside.](https://voltmasters.io/assets/docs/unknown-2.webp)
8. ![The Alpitronic system settings page with the time zone, the stop charging when door opens option and the system time on the charger.](https://voltmasters.io/assets/docs/unknown-4.webp)
9. ![The Alpitronic power settings with the maximum grid power, the fallback power and timeout, and ModBus enabled set to true.](https://voltmasters.io/assets/docs/unknown-5.webp)
10. **Activate the changes by Resetting the charging station**
   
   -   Return to the main screen by clicking **Index**.
   -   Check that no cars are connected to the charging station
   -   Navigate to **Reset** and select **Soft Reset**.
   
   > **Note**
   >
   > *Note: Performing a soft reset ensures all changes are permanently saved and applied.*

![The Alpitronic HyperCharger configuration home with the Network, Status, OCPP, General, Password and Reset sections, and the CCS connector status alongside.](https://voltmasters.io/assets/docs/unknown-2.webp)

![The Alpitronic HyperCharger reset page with a soft reset button that restarts the processes and a hard reset button that reboots the charger.](https://voltmasters.io/assets/docs/image-15.webp)

The charger is now successfully configured and ready for use with the EMS.